Our in depth research into the solar market reveals that more and more customers are choosing solar inverter that support without battery operation. This is especially true in regions where the primary voltage standard is 220V, such as the Philippines, Malaysia, Myanmar, Indonesia, Saudi Arabia, the UAE, Nigeria, Kenya, and South Africa, etc. For most commercial, industrial, or home users, battery typically account for 30% to 50% of the total system cost, posing not only a high initial investment but also requiring regular replacement and maintenance. Solar inverter that support without battery operation can directly convert the DC power generated by solar panels into 220V AC power for loads, enabling "self-use" during the day. This effectively reduces system construction costs while avoiding the maintenance and lifespan risks associated with battery.

For users with relatively stable power grids and concentrated daytime electricity consumption, solar power can be used to directly operate key loads such as air conditioners, refrigerators, water pumps, and office equipment without the need for expensive energy storage systems, resulting in solar system configuration with lower investment and faster returns.
Whether inverter can function properly without battery depends on its type and the stability of its input power. On grid inverter connect directly to the grid, converting DC power generated by solar panels into AC power for input. They lack energy storage and rely on the grid voltage for synchronization. If the grid loses power, the inverter automatically shuts down. Traditional off grid inverter require batteries for stable startup and output. Otherwise, fluctuations in solar power levels can cause frequent shutdowns. Even though some off grid inverter on the market can operate directly with solar panels, the lack of a battery buffer means their output power is completely limited by fluctuations in photovoltaic input. If sunlight decreases or is interrupted, such as on cloudy days or at night, the inverter will immediately stop supplying power, resulting in poor system reliability. However, Xindun's hybrid inverter operate without battery. They prioritize solar power for loads and automatically switch to the mains when sunlight is insufficient, ensuring continuous power supply. During the day, users can directly convert solar power into 220 volts AC power for loads without battery. There is a drawback here. If you don't have batteries or mains power, the system adjusts output power based on real time solar input, which may cause solar system instability under load. If you need to convert solar to 220 volt without battery, it's generally recommended to load some low power appliances.
For many businesses and households, the primary concerns when investing in a solar system are cost and return. Batteries, as a component of solar system, typically account for one-third to even half of the total system cost. For a typical off grid household system, a 100Ah, 24V lead-acid battery costs approximately 500-800 RMB. For basic nighttime power, two or three batteries are typically required, bringing the total battery cost to 1000-2400 RMB. Longer life lithium batteries are more expensive, with a single 24 Volts, 100Ah lithium battery costing approximately 1500-2000 RMB.
A without battery 220 Volts solar inverter eliminates the battery purchase cost and offers a simpler structure, requiring only two core components: solar panels and an inverter. This can reduce the initial total investment by 20%-40%. For example, a system powering a 300W load, such as lighting, refrigerators, or small appliances, would cost approximately 5,000-6,000 RMB (including solar panels, inverter, and two lead-acid batteries) with a battery based solution. A without battery solution only costs 3,000-4,000 RMB (including solar panels and a without battery inverter). This significantly lowers the barrier to entry for ordinary users trying solar power and is particularly suitable for families on a budget, outdoor enthusiasts, or small businesses.
Battery in solar power system require regular maintenance and replacement, which increases operating costs. Without battery system avoid issues such as battery lifespan, capacity fading, and regular replacement, thus reducing long term costs and improving reliability.
Battery can cause some environmental pollution, but without battery off grid solar inverter contribute to a cleaner and more sustainable energy ecosystem, aligning with global green and sustainable development concepts.
Hybrid solar inverter without battery can provide stable power in a variety of environments and are particularly suitable for remote areas with limited or no access to traditional power grids. In these locations, inverters can directly convert solar energy into AC power, providing reliable electricity to homes, offices, or small industrial loads without relying on expensive battery storage systems.
In agricultural applications, without battery off grid solar inverter provide sustainable power support for remote farmland and orchards. Since most agricultural operations occur during the day, 24/7 power is not required. Without battery inverter can directly power these loads using solar energy, providing a sustainable and cost effective solution for remote farms.
Without battery off grid inverter also offer unique advantages in emergency disaster relief or temporary resettlement scenarios. They can be quickly deployed to immediately provide power to rescue efforts, support critical equipment, and help communities quickly restore basic functions after power outages or disasters.
Below, we recommend five Xindun solar inverters that can convert solar to 220 volts directly. Click the image links for more details:
|
HP PLUS+ Solar Inverter Without Battery 5KW/10KW/12KW DC 48 Volts to AC 220Volts Supports parallel operation. 5KW can connect up to 9 units in parallel, 45KW, 10KW/12KW can connect up to 6 units in parallel, and 60KW/72KW, and 10KW/12KW support time sharing charging and discharging settings to take advantage of peak and valley electricity prices and save electricity costs. |
|
|
HFP Solar Inverter Without Battery 1KW-12.3KW DC 12/24/48 Volts to AC 220 Volts Supports off grid, grid connected, hybrid and without battery flexible working mode settings, built in MPPT solar controller, maximum solar input voltage up to 500Vdc. |
|
|
HFP-S Solar Inverter Without Battery 3.3KW-12.3KW DC 24/48 Volts to AC 220 Volts The dual AC output design ensures that the voltage, phase, and frequency of the two AC outputs are completely consistent. It is suitable for powering two loads simultaneously, avoiding energy loss and equipment abnormalities caused by phase difference, and improving system stability and reliability. |
|
|
HFP-C Solar Inverter Without Battery 4.3KW-12/3KW DC 24/48 Volts to AC 220 Volts It adopts a stylish RGB ring light strip design to intuitively display the operating status; equipped with dual AC output function, it can power multiple loads simultaneously, support multi-scenario applications, and improve system compatibility and operating efficiency. |
|
|
HFP-E Solar Inverter Without Battery3.3KW-12.3KW DC 24/48 Volts to AC 220 Volts Supports detachable LCD remote control panel design, which facilitates installation and remote operation in different scenarios. |